Dodge Avenger          1995-00

keys Programming

When

  • Keys added or replaced.

How

NOTE: Two programmed keys must be available for the following procedure to operate.

  • Obtain all keys

NOTE: Any existing keys not used during programming will become inoperative.

  • Using first programmed key, proceed as follows:

o   Turn ignition switch ON ad wait 5 seconds, return to OFF position and remove key.

o   Within 7 seconds insert second programmed key and switch ignition ON.

o   Ensure immobilizer warning lamp flashes twice.

  • If not, repeat procedure starting from the beginning.
  • Switch ignitions OFF and remove key.
  • For each additional new key proceed as follows:

o   Insert new key and switch ignition ON within 7 seconds of last key removed.

o   Wait a few seconds.

o   Ensure immobilizer warning lamp illuminates for 3 seconds indicating programming complete.

  • If not repeat procedure starting from the beginning.
  • Replacement keys can also be programming using diagnostic equipment.

NOTE: a maximum of 8 keys can be programmed.

 

Dodge Avenger          2008-09

keys  Programming

When

  • Keys added or replaced.

How

NOTE: two programmed key transmitters must be available for the following procedure to operate

·         Obtain all keys

·         Using first programmed key, proceed as follows:

o   Turn ignition switch ON and wait 3 seconds, return to OFF position and remove key.

o   Insert second programmed key and switch ignition ON

o   Wait approximately 10 seconds.

·         Ensure immobilizer warning lamp begins to flash and an acoustic signal is emitted.

·         Switch ignition OFF and remove key.

·         Within 60 seconds, Insert new key and switch ignition ON.

o   Wait approximately 10 seconds.

o   Ensure acoustic signal is emitted and immobilizer warning lamp remains illuminated for 3 seconds indicating programming complete.

·         For each additional key repeat procedure starting from the beginning.

·         Replacement keys can also be programmed using diagnostic equipment.

NOTE: A maximum of 6 key can be programmed.